xiaozhi-esp32-server/docs/ota-upgrade-guide.md
lapy ed8c012588 docs: English-first documentation, images, and licensing
- Curated guides under docs/; trim China-only integration docs and screenshots

- Root and main README set aligned with westernized product positioning

- LICENSE text update where applicable
2026-04-25 17:05:22 +01:00

4 KiB

OTA Firmware Upgrade Guide for Single-Module Deployments

This guide explains how to configure automatic OTA firmware upgrades when you are running the single-module xiaozhi-server deployment.

If you are using the full-module deployment, you can skip this guide.

Overview

In single-module mode, xiaozhi-server includes built-in OTA firmware management. It can check device versions, match the correct firmware for the device model, and serve updated firmware automatically.

Prerequisites

  • You already have a working single-module deployment of xiaozhi-server
  • Your device can connect to the server successfully

Step 1: Prepare the firmware file

1. Create the firmware directory

Firmware files must be placed in data/bin/. Create it if it does not already exist:

mkdir -p data/bin

2. Follow the required filename format

Firmware files must follow this format:

{device_model}_{version}.bin

Rules:

  • device_model: the device model name, for example lichuang-dev or bread-compact-wifi
  • version: must begin with a number and may contain letters, dots, underscores, and hyphens
  • the file extension must be .bin

Examples:

bread-compact-wifi_1.6.6.bin
lichuang-dev_2.0.0.bin

3. Copy the correct firmware artifact

Copy the OTA upgrade artifact into data/bin/:

Important: use xiaozhi.bin, not the full firmware image merged-binary.bin.

cp xiaozhi.bin data/bin/device_model_version.bin

Example:

cp xiaozhi.bin data/bin/bread-compact-wifi_1.6.6.bin

Step 2: Configure the public access address

This step is required only for public internet deployments.

If your xiaozhi-server instance is exposed through a public IP or domain, you must configure server.vision_explain because the OTA download URL is derived from that address.

If your deployment is LAN-only, you can skip this step.

Why this is required

When xiaozhi-server builds OTA download URLs, it uses the host and port from the vision_explain setting. If that value is missing or incorrect, devices will not be able to download firmware updates.

How to configure it

Open data/.config.yaml, find the server section, and set vision_explain:

server:
  vision_explain: http://your-domain-or-ip:8003/mcp/vision/explain

Examples:

LAN deployment:

server:
  vision_explain: http://192.168.1.100:8003/mcp/vision/explain

Public domain deployment:

server:
  vision_explain: http://yourdomain.com:8003/mcp/vision/explain

Notes

  • The domain or IP must be reachable by the device
  • If you use Docker, do not use internal-only addresses such as 127.0.0.1 or localhost
  • If you use nginx as a reverse proxy, enter the externally reachable host and port, not the internal service port

Troubleshooting

1. The device does not receive an update

Check the following:

  • the firmware file name matches {model}_{version}.bin
  • the firmware file is in data/bin/
  • the device model matches the model segment in the file name
  • the firmware version is newer than the current device version
  • the server logs show OTA requests being handled

2. The device cannot reach the download URL

Check the following:

  • server.vision_explain points to the correct public host or IP
  • the configured port is correct, usually 8003
  • the device can reach that public address
  • you are not using a Docker-internal address such as 127.0.0.1
  • the firewall allows the required port
  • if you use nginx, you entered the public host and port rather than the internal app port

3. How to confirm the device's current version

Look at the OTA request logs. They include the version reported by the device:

[ota_handler] - Device AA:BB:CC:DD:EE:FF firmware is already up to date: 1.6.6

4. The new firmware file is not detected immediately

There is a cache window of 30 seconds by default. You can:

  • wait 30 seconds and try the OTA request again
  • restart the xiaozhi-server service
  • reduce the firmware_cache_ttl setting if you want faster refreshes