# OTA Firmware Upgrade Guide for Single-Module Deployments
|
|
|
|
This guide explains how to configure automatic OTA firmware upgrades when you are running the single-module `xiaozhi-server` deployment.
|
|
|
|
If you are using the full-module deployment, you can skip this guide.
|
|
|
|
## Overview
|
|
|
|
In single-module mode, `xiaozhi-server` includes built-in OTA firmware management. It can check device versions, match the correct firmware for the device model, and serve updated firmware automatically.
|
|
|
|
## Prerequisites
|
|
|
|
- You already have a working single-module deployment of `xiaozhi-server`
|
|
- Your device can connect to the server successfully
|
|
|
|
## Step 1: Prepare the firmware file
|
|
|
|
### 1. Create the firmware directory
|
|
|
|
Firmware files must be placed in `data/bin/`. Create it if it does not already exist:
|
|
|
|
```bash
|
|
mkdir -p data/bin
|
|
```
|
|
|
|
### 2. Follow the required filename format
|
|
|
|
Firmware files must follow this format:
|
|
|
|
```text
|
|
{device_model}_{version}.bin
|
|
```
|
|
|
|
Rules:
|
|
|
|
- `device_model`: the device model name, for example `lichuang-dev` or `bread-compact-wifi`
|
|
- `version`: must begin with a number and may contain letters, dots, underscores, and hyphens
|
|
- the file extension must be `.bin`
|
|
|
|
Examples:
|
|
|
|
```text
|
|
bread-compact-wifi_1.6.6.bin
|
|
lichuang-dev_2.0.0.bin
|
|
```
|
|
|
|
### 3. Copy the correct firmware artifact
|
|
|
|
Copy the OTA upgrade artifact into `data/bin/`:
|
|
|
|
Important: use `xiaozhi.bin`, not the full firmware image `merged-binary.bin`.
|
|
|
|
```bash
|
|
cp xiaozhi.bin data/bin/device_model_version.bin
|
|
```
|
|
|
|
Example:
|
|
|
|
```bash
|
|
cp xiaozhi.bin data/bin/bread-compact-wifi_1.6.6.bin
|
|
```
|
|
|
|
## Step 2: Configure the public access address
|
|
|
|
This step is required only for public internet deployments.
|
|
|
|
If your `xiaozhi-server` instance is exposed through a public IP or domain, you must configure `server.vision_explain` because the OTA download URL is derived from that address.
|
|
|
|
If your deployment is LAN-only, you can skip this step.
|
|
|
|
### Why this is required
|
|
|
|
When `xiaozhi-server` builds OTA download URLs, it uses the host and port from the `vision_explain` setting. If that value is missing or incorrect, devices will not be able to download firmware updates.
|
|
|
|
### How to configure it
|
|
|
|
Open `data/.config.yaml`, find the `server` section, and set `vision_explain`:
|
|
|
|
```yaml
|
|
server:
|
|
vision_explain: http://your-domain-or-ip:8003/mcp/vision/explain
|
|
```
|
|
|
|
Examples:
|
|
|
|
LAN deployment:
|
|
|
|
```yaml
|
|
server:
|
|
vision_explain: http://192.168.1.100:8003/mcp/vision/explain
|
|
```
|
|
|
|
Public domain deployment:
|
|
|
|
```yaml
|
|
server:
|
|
vision_explain: http://yourdomain.com:8003/mcp/vision/explain
|
|
```
|
|
|
|
### Notes
|
|
|
|
- The domain or IP must be reachable by the device
|
|
- If you use Docker, do not use internal-only addresses such as `127.0.0.1` or `localhost`
|
|
- If you use `nginx` as a reverse proxy, enter the externally reachable host and port, not the internal service port
|
|
|
|
## Troubleshooting
|
|
|
|
### 1. The device does not receive an update
|
|
|
|
Check the following:
|
|
|
|
- the firmware file name matches `{model}_{version}.bin`
|
|
- the firmware file is in `data/bin/`
|
|
- the device model matches the model segment in the file name
|
|
- the firmware version is newer than the current device version
|
|
- the server logs show OTA requests being handled
|
|
|
|
### 2. The device cannot reach the download URL
|
|
|
|
Check the following:
|
|
|
|
- `server.vision_explain` points to the correct public host or IP
|
|
- the configured port is correct, usually `8003`
|
|
- the device can reach that public address
|
|
- you are not using a Docker-internal address such as `127.0.0.1`
|
|
- the firewall allows the required port
|
|
- if you use `nginx`, you entered the public host and port rather than the internal app port
|
|
|
|
### 3. How to confirm the device's current version
|
|
|
|
Look at the OTA request logs. They include the version reported by the device:
|
|
|
|
```text
|
|
[ota_handler] - Device AA:BB:CC:DD:EE:FF firmware is already up to date: 1.6.6
|
|
```
|
|
|
|
### 4. The new firmware file is not detected immediately
|
|
|
|
There is a cache window of 30 seconds by default. You can:
|
|
|
|
- wait 30 seconds and try the OTA request again
|
|
- restart the `xiaozhi-server` service
|
|
- reduce the `firmware_cache_ttl` setting if you want faster refreshes
|