# TEN VAD Integration Summary ## Overview TEN VAD has been successfully integrated into the XiaoZhi ESP32 Server with **full cross-platform support**. Two versions are now available: 1. **TEN VAD Original**: Linux-only version using pip package 2. **TEN VAD ONNX**: Cross-platform version supporting Windows, Linux, and macOS ## Files Added/Modified ### New Files Created: 1. **`core/providers/vad/ten_vad.py`** - Main TEN VAD provider implementation 2. **`scripts/install_ten_vad.py`** - Installation script for TEN VAD 3. **`scripts/test_ten_vad.py`** - Test script to verify TEN VAD installation 4. **`examples/ten_vad_example.py`** - Usage example and configuration guide 5. **`docs/ten-vad-integration.md`** - Comprehensive integration documentation ### Modified Files: 1. **`requirements.txt`** - Added `ten-vad==0.1.0` dependency 2. **`data/.config.yaml`** - Added TEN VAD configuration section 3. **`README.md`** - Updated VAD section to include TEN VAD ## Configuration TEN VAD configuration has been added to `.config.yaml`: ```yaml VAD: TenVAD: type: ten_vad model_path: models/ten-vad sample_rate: 16000 frame_size: 512 threshold: 0.5 threshold_low: 0.2 min_silence_duration_ms: 1000 frame_window_threshold: 3 ``` ## Usage To use TEN VAD, update the selected module in your configuration: ```yaml selected_module: VAD: TenVAD # Change from SileroVAD to TenVAD ``` ## Installation Steps 1. **Install TEN VAD package:** ```bash cd main/xiaozhi-server python scripts/install_ten_vad.py ``` 2. **Test the installation:** ```bash python scripts/test_ten_vad.py ``` 3. **Update configuration:** ```yaml selected_module: VAD: TenVAD ``` 4. **Start the server:** ```bash python app.py ``` ## Key Features - **High Performance**: TEN VAD provides accurate voice activity detection - **Configurable Thresholds**: Dual threshold system for stable detection - **Sliding Window**: Prevents false positives with frame-based detection - **Easy Integration**: Follows the same interface as existing VAD providers - **Comprehensive Logging**: Debug information for troubleshooting ## Architecture Integration TEN VAD integrates seamlessly with the existing VAD architecture: ``` core/utils/vad.py (Factory) ↓ core/providers/vad/ten_vad.py (TEN VAD Implementation) ↓ core/providers/vad/base.py (VAD Interface) ``` The integration follows the same pattern as other VAD providers: - Implements `VADProviderBase` interface - Uses the factory pattern for instantiation - Processes Opus-encoded audio packets - Returns boolean voice activity detection results ## Configuration Options ### Sensitivity Levels: - **Sensitive**: `threshold: 0.3, threshold_low: 0.1` - **Balanced**: `threshold: 0.5, threshold_low: 0.2` (default) - **Conservative**: `threshold: 0.7, threshold_low: 0.4` ### Performance Tuning: - `frame_size`: Audio processing frame size (default: 512) - `frame_window_threshold`: Frames needed for voice detection (default: 3) - `min_silence_duration_ms`: Silence duration to end speech (default: 1000ms) ## Testing The integration includes comprehensive testing: 1. **Installation Test**: Verifies TEN VAD package installation 2. **Provider Creation Test**: Tests VAD provider instantiation 3. **Audio Processing Test**: Tests audio processing pipeline 4. **Configuration Loading Test**: Tests factory method integration ## Troubleshooting Common issues and solutions: 1. **Import Error**: Install TEN VAD with `pip install ten-vad` 2. **Model Loading Error**: Ensure model path exists and is accessible 3. **Performance Issues**: Adjust `frame_size` or `sample_rate` 4. **Detection Issues**: Tune threshold values for your environment ## Documentation - **Integration Guide**: `docs/ten-vad-integration.md` - **Usage Example**: `examples/ten_vad_example.py` - **Installation Script**: `scripts/install_ten_vad.py` - **Test Script**: `scripts/test_ten_vad.py` ## Next Steps 1. Test TEN VAD with real audio input 2. Compare performance with Silero VAD 3. Fine-tune configuration parameters 4. Consider adding more VAD providers if needed ## Notes - TEN VAD models will be downloaded automatically on first use - The integration maintains backward compatibility with existing VAD providers - All existing VAD functionality remains unchanged - TEN VAD can be easily switched on/off via configuration