# OTA Firmware Upgrade Guide for Single-Module Deployments This guide explains how to configure automatic OTA firmware upgrades when you are running the single-module `xiaozhi-server` deployment. If you are using the full-module deployment, you can skip this guide. ## Overview In single-module mode, `xiaozhi-server` includes built-in OTA firmware management. It can check device versions, match the correct firmware for the device model, and serve updated firmware automatically. ## Prerequisites - You already have a working single-module deployment of `xiaozhi-server` - Your device can connect to the server successfully ## Step 1: Prepare the firmware file ### 1. Create the firmware directory Firmware files must be placed in `data/bin/`. Create it if it does not already exist: ```bash mkdir -p data/bin ``` ### 2. Follow the required filename format Firmware files must follow this format: ```text {device_model}_{version}.bin ``` Rules: - `device_model`: the device model name, for example `lichuang-dev` or `bread-compact-wifi` - `version`: must begin with a number and may contain letters, dots, underscores, and hyphens - the file extension must be `.bin` Examples: ```text bread-compact-wifi_1.6.6.bin lichuang-dev_2.0.0.bin ``` ### 3. Copy the correct firmware artifact Copy the OTA upgrade artifact into `data/bin/`: Important: use `xiaozhi.bin`, not the full firmware image `merged-binary.bin`. ```bash cp xiaozhi.bin data/bin/device_model_version.bin ``` Example: ```bash cp xiaozhi.bin data/bin/bread-compact-wifi_1.6.6.bin ``` ## Step 2: Configure the public access address This step is required only for public internet deployments. If your `xiaozhi-server` instance is exposed through a public IP or domain, you must configure `server.vision_explain` because the OTA download URL is derived from that address. If your deployment is LAN-only, you can skip this step. ### Why this is required When `xiaozhi-server` builds OTA download URLs, it uses the host and port from the `vision_explain` setting. If that value is missing or incorrect, devices will not be able to download firmware updates. ### How to configure it Open `data/.config.yaml`, find the `server` section, and set `vision_explain`: ```yaml server: vision_explain: http://your-domain-or-ip:8003/mcp/vision/explain ``` Examples: LAN deployment: ```yaml server: vision_explain: http://192.168.1.100:8003/mcp/vision/explain ``` Public domain deployment: ```yaml server: vision_explain: http://yourdomain.com:8003/mcp/vision/explain ``` ### Notes - The domain or IP must be reachable by the device - If you use Docker, do not use internal-only addresses such as `127.0.0.1` or `localhost` - If you use `nginx` as a reverse proxy, enter the externally reachable host and port, not the internal service port ## Troubleshooting ### 1. The device does not receive an update Check the following: - the firmware file name matches `{model}_{version}.bin` - the firmware file is in `data/bin/` - the device model matches the model segment in the file name - the firmware version is newer than the current device version - the server logs show OTA requests being handled ### 2. The device cannot reach the download URL Check the following: - `server.vision_explain` points to the correct public host or IP - the configured port is correct, usually `8003` - the device can reach that public address - you are not using a Docker-internal address such as `127.0.0.1` - the firewall allows the required port - if you use `nginx`, you entered the public host and port rather than the internal app port ### 3. How to confirm the device's current version Look at the OTA request logs. They include the version reported by the device: ```text [ota_handler] - Device AA:BB:CC:DD:EE:FF firmware is already up to date: 1.6.6 ``` ### 4. The new firmware file is not detected immediately There is a cache window of 30 seconds by default. You can: - wait 30 seconds and try the OTA request again - restart the `xiaozhi-server` service - reduce the `firmware_cache_ttl` setting if you want faster refreshes